Hardware thin aluminum alloy vibration plate vibration fatigue or too slow, sporadic or irregular feeding, may be caused by the following reasons:
1, the spring break, which needs to replace the new spring piece up and debug to the machine stable.
2, the floor is too thin.
3, the installation of surface defects, lack of hardness. If suspended in the equipment table, will cause the vibration is too weak, the thickness of the table to reach at least 1-1/2, so that it will not absorb vibration,
Cylindrical support legs must be equipped with a triangular support.
4, mesa is not level.
5, metal sheet Aluminum Alloy vibration plate with debris.
6, the gap is not suitable for the electromagnet.
7, the machine parts lead to the fast pace of decline in the vibration plate.
8, material too much.
9, the power grid fluctuations caused by voltage instability.
10, parts of the problem: irregular parts or oil and other reasons.
11, metal sheet metal vibration plate adjustment...